Specifications
|
|
Fluid
|
Air and gas
|
Repeatability
|
±1.5 % of full range
|
Dead
band
|
Fixed. 0.25 ~ 0.8 kPa or less
|
Differential
pressure range (kPa)
|
0 ~ 4 kPa to 0 ~ 20 kPa
|
Static
pressure
|
500 kPa
|
Working
temperature
|
Ambient : -20 ~ 65 °C
Fluid : Max. 60 °C
|
Degress
of protection
|
EN60529/IEC529/IP65
|
Pressure
connection
|
Stainless steel (316L SS)
|
Element
|
Bellows : Stainless steel (316L SS)
Gasket : PTFE
|
Mounting
|
Surface wall mounting
|
Setpoint
adjustment
|
Internal
|
Contact
|
One SPDT
Two SPDT (Only available with single setpoint)
|
Contact
rating
|
SPDT contact rating
AC 125 V / 250 V, 15 A
DC 125 V, 0.4 A for resistance load
DC 125V, 0.03 A for inductive load
|
Conduit
connection
|
¾" PF (F)
|
Process
connection
|
¼" NPT (F)
|
Operating
environment
|
Hazardous area refer to the explosion-proof item for
information
|
Certificates
|
KCS Ex d IIC T6
|
Option
|
3-way manifold valve
5-way manifold valve
|