Range:

0 – 600 ppm “free” water

Resolution:

1 ppm, lower Range

Accuracy:

Up to ± 10 ppm below 100 ppm

Response Time:

< 5 sec.

Linearity:

0 – 100 ppm better than ± 2 %

Display:

Full Colour Graphic

Datalogging System

Yes

Power Supply:

24 V – 240 V AC or DC

Consumption:

< 10 VA

Alarm Points 1, 2:

Adjustable, (Works adjustment 70 ppm)

Alarm 1 Operating Delay:

 (for annunciation purpose)

Adjustable between 1 – 540 sec. (Works adjustment 2 sec.)

Alarm 2 Operating Delay:

 (for control purposes)

Adjustable between 1 – 540 sec. (Works adjustment 10 sec.)

Alarm Indication:

(Alarm 1, 2, System Fault)

Red visual indicator

Alarm Contact Rating: (Alarm 1, 2, System Fault)

Potential free 1 pole change over contacts, 3 A / 240 V AC

Output Signal:

0 – 20 mA, ext. Load < 150 Ω Output range adjustable

Sample Pressure:

0 – 10 bar

Sample Flow:

Approx. 2 l/min

Sample Temperature:

+ 1 to + 65° C

Ambient Temperature:

+ 1 to + 45° C

Size: Computer Unit

200 mm W x 200 mm H x 120 mm D

Size: Measuring Cell

130 mm W x 55 mm H x 70 mm D

Weight:

4 kg

Degree of Protection:

IP 65

Pipe Connections:

R ¼" Female